    Methodology

    This reliability and confidence sample size calculator tells you how many units to test to demonstrate a reliability at a chosen confidence level. Enter the reliability, the confidence and the number of failures you will allow, and it returns the sample size with the working.

    Sample size 29 units
    Reliability90%
    Confidence95%
    Failures allowed0
    Zero-failure sample size29
    Sample sizes for 90% reliability at 95% confidence
    Failures allowedUnits to test
    029
    146
    261
    376
    489
    5103
    Show the working, step by step
    1. With no failures allowed, use the success-run formula.

      n = ln(1 − C) ÷ ln(R) = ln(0.05) ÷ ln(0.9) = 28.4332

    2. Round up to a whole unit.

      n = 29

    If all 29 units pass, you can state 90% reliability with 95% confidence.

    The success-run formula

    n = ln(1 − C) ÷ ln(R)

    R is the reliability to demonstrate and C the confidence, both as decimals, and n is rounded up. It comes from a simple argument. If the true reliability were only R, the chance that n units in a row all pass is Rn. Choose n so that chance is no more than 1 − C, and passing the test becomes strong evidence that the reliability is at least R.

    Worked example

    Show 90% reliability with 95% confidence, no failures allowed.

    1. 1 − C = 1 − 0.95 = 0.05, and ln(0.05) = −2.9957.
    2. ln(R) = ln(0.90) = −0.10536.
    3. n = −2.9957 ÷ −0.10536 = 28.43, rounded up to 29 units.

    Check: 0.9029 = 0.047, which is below 0.05, while 0.9028 = 0.052 is not. So 29 is the smallest sample that works.

    Common reliability and confidence sample sizes

    Reliability / confidence0 failures1 failure2 failures
    90% / 90%223852
    90% / 95%294661
    95% / 90%4577105
    95% / 95%5993124
    99% / 90%230388531
    99% / 95%299473628

    Raising reliability costs far more than raising confidence. Going from 95% to 99% reliability at 95% confidence takes the zero-failure sample from 59 to 299.

    When failures are allowed

    Σ C(n, i) (1 − R)^i R^(n − i) ≤ 1 − C, summed for i = 0 to f

    With f failures allowed, the calculator finds the smallest n for which a product at exactly the target reliability would produce f or fewer failures with probability no more than 1 − C. That is a cumulative probability from the binomial distribution. A plan that allows failures needs more units, but a single failure does not end the test.

    When to use it

    • Design verification and process validation. Showing a product or process meets a requirement on pass or fail tests, as in medical device and automotive work.
    • Attribute data only. Each unit passes or fails. For measured values, a tolerance interval usually needs far fewer units.
    • Not for surveys. For a poll or an estimate of a mean, use the sample size calculator, which works from the margin of error.
    Reliability and confidence sample size calculator: the worked example on this page, with its result and chart
    Reliability and confidence sample size calculator: the worked example above, at a glance.

    Common questions

    How do you calculate sample size for reliability and confidence?

    With no failures allowed, use the success-run formula n = ln(1 − C) ÷ ln(R), where R is the reliability and C the confidence, and round up. For 90% reliability at 95% confidence, ln(0.05) ÷ ln(0.90) = 28.4, so you test 29 units and all must pass.

    What sample size do I need for 95% confidence and 95% reliability?

    59 units with zero failures. ln(0.05) ÷ ln(0.95) = 58.4, which rounds up to 59. Allowing one failure raises it to 93, and two failures to 124.

    What does 90/95 or 95/95 mean?

    In this field the pair is usually given as reliability / confidence. 95/95 means showing that at least 95% of units meet the requirement, with 95% confidence in that claim. Some documents write confidence first, so check which is which before you use a table.

    What happens if a unit fails during the test?

    A zero-failure plan is failed by a single failure. You cannot simply keep testing until the numbers work. Either investigate and restart, or use a plan chosen in advance that allows failures, which needs a larger sample. Set the number of failures allowed before testing begins.

    Does this apply to measured (variable) data?